12 V vs 24 V vs 48 V for an RV
The voltage you pick doesn't change how much energy your RV uses. It changes the current, and with it the cable, the fuses and which parts you can buy. Here is one RV built three ways by the Sunwire designer.
Open the RV example in the designer
The same RV at 12, 24 and 48 V
These are the RV example's 10 devices, 5 sun hours and 2 days of backup, auto-built by the designer at each voltage with Victron parts where Victron makes them. (The RV example itself pins a six-panel roof array and three 100 Ah batteries; these are fresh auto-builds from its devices, so the panels and batteries can differ.)
| 12 V | 24 V | 48 V | |
|---|---|---|---|
| Daily use | 3,348 Wh | 3,348 Wh | 3,348 Wh |
| Battery bank | 4 × Victron LiFePO4 12.8V 200Ah Smart (9,600 Wh) | 2 × Victron LiFePO4 25.6V 200Ah Smart (9,600 Wh) | 2 × LiTime 51.2V 100Ah LiFePO4 (9,600 Wh) |
| Same bank in amp-hours | 800 Ah | 400 Ah | 200 Ah |
| Inverter | Victron MultiPlus-II 12/3000/120 (2,400 W) | Victron MultiPlus-II 24/3000/70 (2,400 W) | Victron MultiPlus-II 48/5000/70 (4,000 W) |
| Inverter current from the battery | 235 A | 118 A | 98 A |
| Inverter cable (5 ft run) | 2/0 AWG | 4 AWG | 4 AWG |
| Main battery fuse | 400 A | 200 A | 150 A |
| Charge controller | Victron SmartSolar MPPT 150/100-Tr | Victron SmartSolar MPPT 150/60-Tr | Victron SmartSolar MPPT 150/45 |
| Solar | 3 × Qcells Q.TRON BLK M-G2+ 425 (1,275 W) | 3 × Qcells Q.TRON BLK M-G2+ 425 (1,275 W) | 3 × Qcells Q.TRON BLK M-G2+ 425 (1,275 W) |
| 12 V converter | Not needed | Victron Orion 24/12-30 non-isolated | Victron Orion 48/12-60 non-isolated |
Sunwire's rules of thumb: panels make 75% of their rating in peak sun, 90% of a lithium battery is usable, and an inverter delivers 90% of the energy it draws. How the numbers work.
Why the current drops
Power is volts × amps, so doubling the voltage halves the current for the same watts. Sunwire works out an inverter's draw from the battery as its watts ÷ (battery volts × 0.85), allowing for losses at full load:
| Voltage | Sunwire's math | Current |
|---|---|---|
| 12 V | 2,400 W ÷ (12 × 0.85) | 235 A |
| 24 V | 2,400 W ÷ (24 × 0.85) | 118 A |
| 48 V | 4,000 W ÷ (48 × 0.85) | 98 A |
At 48 V the Victron inverter auto-build picks is larger (Victron MultiPlus-II 48/5000/70 (4,000 W)), so its full-load current is more than the voltage alone explains. For the same 2,400 W it would be 59 A at 48 V.
Cable is sized for that current. Sunwire picks the smallest gauge that carries 125% of it and keeps the voltage drop under 3% (see the solar wire size chart). The main battery fuse is 125% of the largest current the system can draw, rounded up to 100, 150, 200, 300 or 400 A. The designer suggests 24 or 48 V once a 12 V inverter reaches 3,000 W.
What happens to 12 V devices
Most DC devices, like a fridge, fan, pump or lights, run on 12 V. On a 12 V system they run from the fuse block directly. At 24 or 48 V, auto-build adds a step-down converter between the battery and the fuse block, sized for the DC devices' watts ÷ 12 V, with 10% to spare when it picks a model. For this RV that is 275 W ÷ 12 = 23 A.
Which to pick
- 12 V keeps every 12 V device on the battery directly, with no converter. Its cost is current: here the inverter pulls 235 A, on 2/0 AWG cable and a 400 A main fuse.
- 24 V halves the current for the same watts (118 A here) and the cable shrinks to 4 AWG, for the price of a converter.
- 48 V cuts the current for the same watts to a quarter (59 A for 2,400 W; 98 A for the larger inverter picked here, on 4 AWG). Check that the batteries and inverter you want come in 48 V.
Quick answers
Is 12 V, 24 V or 48 V better for an RV?
For the same RV devices, Sunwire's inverter draws about 235 A from a 12 V battery, 118 A at 24 V and 98 A at 48 V. Less current means thinner cable and smaller fuses: the inverter cable goes from 2/0 AWG at 12 V to 4 AWG at 48 V. The energy you use each day, 3,348 Wh, is the same at every voltage. (At 48 V the designer picks a larger inverter, 4,000 W.)
Do I need a converter on a 24 V or 48 V RV?
Yes, if you have 12 V devices like a fridge, fan or lights. Auto-build adds a step-down converter to feed the fuse block: for this RV's 275 W of DC devices, about 23 A at 12 V.
Does a higher voltage mean a smaller battery?
No. The energy is the same; only the amp-hours change, because amp-hours = watt-hours ÷ volts. A 9,600 Wh bank is 800 Ah at 12 V, 400 Ah at 24 V and 200 Ah at 48 V.
Make it yours
Open the RV example, then change System voltage on the Check tab. Sunwire re-fits the batteries, inverter, charge controller, converter and main fuse for the new voltage, lists every change, and offers to rebuild the whole system from your devices.
Open the RV in the designer See the RV example
More sizing questions:
- How many solar panels to run a fridge in a van
- What size battery for an off-grid cabin
- Solar wire size chart
- How many solar panels to run an RV air conditioner
- What size inverter do I need